<?xml version="1.0" encoding="UTF-8"?><?xml-model href="http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng" schematypens="http://relaxng.org/ns/structure/1.0"?><TEI xmlns="http://www.tei-c.org/ns/1.0"><teiHeader>
    <fileDesc>
      <titleStmt><title type="main">Der Fernsprecher in Ueberland-Kraftwerken.</title><title type="sub">Von G. Quaink.</title>
        
        
        <editor>
          <orgName>Dingler Online – Das digitalisierte Polytechnische Journal</orgName>
        </editor>
        <respStmt>
          <orgName ref="https://d-nb.info/gnd/1220138-8">Humboldt-Universität zu Berlin</orgName>
          <resp>
            <note type="remarkResponsibility">Projektträger</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName ref="https://d-nb.info/gnd/141535091">
            <surname>Kassung</surname>
            <forename>Christian</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Projektleitung Humboldt-Universität</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName ref="https://d-nb.info/gnd/1204665788">
            <surname>Hug</surname>
            <forename>Marius</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Wissenschaftlicher Mitarbeiter Humboldt-Universität</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName>
            <surname>Zehnder</surname>
            <forename>Deborah</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Projektkoordination</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName>
            <surname>Luzardo</surname>
            <forename>Laura</forename>
          </persName>
          <persName>
            <surname>Schäfer</surname>
            <forename>Una</forename>
          </persName>
          <persName>
            <surname>Bechmann</surname>
            <forename>Antonia</forename>
          </persName>
          <persName>
            <surname>Daniel</surname>
            <forename>Diana</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Studentische Hilfskräfte</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName>
            <surname>Wiegand</surname>
            <forename>Frank</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Programmierung</note>
          </resp>
        </respStmt>
        <respStmt>
          <orgName ref="https://d-nb.info/gnd/5165770-3">Sächsische Landesbibliothek – Staats- und Universitätsbibliothek Dresden</orgName>
          <resp>
            <note type="remarkResponsibility">Kooperationspartner Bibliothek</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName ref="https://d-nb.info/gnd/114684476X">
            <surname>Rohrmüller</surname>
            <forename>Marc</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Projektkoordination Bibliothek</note>
          </resp>
        </respStmt>
        <respStmt>
          <orgName ref="https://d-nb.info/gnd/2007744-0">Deutsche Forschungsgemeinschaft</orgName>
          <resp>
            <note type="remarkResponsibility">Projektförderung</note>
          </resp>
        </respStmt>
        <respStmt>
          <orgName ref="https://d-nb.info/gnd/1064129226">Editura GmbH &amp; Co. KG, Berlin</orgName>
          <resp>
            <note type="remarkResponsibility">Volltextdigitalisierung</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName>
            <surname>Gödel</surname>
            <forename>Martina</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Projektkoordination und Basic Encoding nach den Richtlinien der TEI für die Editura GmbH &amp; Co. KG</note>
          </resp>
        </respStmt>
        <respStmt>
          <orgName ref="https://www.clarin-d.de/">CLARIN-D</orgName>
          <resp>
            <note type="remarkResponsibility">Langfristige Bereitstellung</note>
          </resp>
        </respStmt>
      </titleStmt>
      <editionStmt>
        <edition n="1"/>
      </editionStmt>
      <publicationStmt>
        <publisher>
          <email>wiegand@bbaw.de</email>
          <orgName role="project">Deutsches Textarchiv (Dingler)</orgName>
          <orgName role="hostingInstitution" xml:lang="en" ref="https://d-nb.info/gnd/2131094-4">Berlin-Brandenburg Academy of Sciences and Humanities</orgName>
          <orgName role="hostingInstitution" xml:lang="de" ref="https://d-nb.info/gnd/2131094-4">Berlin-Brandenburgische Akademie der Wissenschaften (BBAW)</orgName>
          <address>
            <addrLine>Jägerstr. 22/23, 10117 Berlin</addrLine>
            <country>Germany</country>
          </address>
        </publisher>
        <pubPlace>Berlin</pubPlace>
        <date type="publication">2022-09-26</date>
        <availability>
          <licence target="https://creativecommons.org/licenses/by-sa/4.0/deed.de">
            <p>Die Textdigitalisate des Polytechnischen Journals stehen unter der Creative-Commons-Lizenz CC BY-SA 4.0.</p>
          </licence>
        </availability>
        <idno>
          <idno type="URLWeb">http://digital.slub-dresden.de/id32199916Z</idno>
          <idno type="URLXML">https://dingler.bbaw.de/xml/articles/ar339005.xml</idno>
        </idno>
      </publicationStmt>
      <sourceDesc><bibl type="JA">Der Fernsprecher in Ueberland-Kraftwerken. In: Dinglers polytechnisches Journal. Bd. 339. Berlin, 1924. S. 19.</bibl>
        
        <biblFull>
          <titleStmt><title type="main">Der Fernsprecher in Ueberland-Kraftwerken.</title><title type="sub">Von G. Quaink.</title>
            
            
          </titleStmt>
          <editionStmt>
            <edition n="1"/>
          </editionStmt>
          <publicationStmt>
            <publisher>Richard Dietze, Verlagsbuchhandlung</publisher>
            <pubPlace>Berlin</pubPlace>
            <date type="publication">1924</date>
          </publicationStmt>
        <seriesStmt><title level="j" type="main" xml:id="pj339">Dinglers polytechnisches Journal. Bd. 339. Berlin, 1924.</title><biblScope unit="volume">1924</biblScope><biblScope unit="issue">339</biblScope><biblScope unit="pages">S. 19</biblScope></seriesStmt></biblFull>
        <msDesc>
          <msIdentifier>
            <repository>SLUB Dresden</repository>
            <idno>
              <idno type="URLWeb">http://digital.slub-dresden.de/id32199916Z</idno>
            </idno>
          </msIdentifier>
        </msDesc>
      </sourceDesc>
    </fileDesc>
    <encodingDesc>
      <projectDesc>
        <p>Optical character recognition and basic TEI encoding by Editura Gesellschaft für
					Verlagsdienstleistungen, Berlin 2012.</p>
      </projectDesc>
      <editorialDecl>
        <hyphenation eol="hard">
          <p>All soft end-of-line hyphenation has been removed. All hard hyphenation coded as U+2010.</p>
        </hyphenation>
        <normalization method="silent">
          <p>No text-decoration elements were captured, such as decorated capital letters at the beginning of
						chapters or text-separators.</p>
          <p>All references to printed sheets were captured.</p>
        </normalization>
        <correction method="markup">
          <p>As far as possible all errata-lists printed in the journal have been realised, using the element
							<gi scheme="TEI">orig</gi> to mark the original text and <gi scheme="TEI">corr</gi> to mark
						the correction given in the errata-list.</p>
        </correction>
        <quotation marks="all">
          <p>All passages set off by quotation marks were marked by the element <gi scheme="TEI">q</gi>
						including the quotation mark inside the tag. In case of repeating quotation marks in front of
						each line, only the first and the last quotation mark was obtained. And the element <gi scheme="TEI">q</gi>'s @type-attribute was set to the value „preline”.</p>
        </quotation>
      </editorialDecl>
      <tagsDecl>
        <rendition xml:id="roman" scheme="css">font-family: "times new roman", times, serif;</rendition>
        <rendition xml:id="wide" scheme="css">letter-spacing: 2pt;</rendition>
        <rendition xml:id="center" scheme="css">text-align: center;</rendition>
        <rendition xml:id="small" scheme="css">font-size: .8em;</rendition>
        <rendition xml:id="x-small" scheme="css">font-size: x-small;</rendition>
        <rendition xml:id="xx-small" scheme="css">font-size: xx-small;</rendition>
        <rendition xml:id="large" scheme="css">font-size: large;</rendition>
        <rendition xml:id="x-large" scheme="css">font-size: x-large;</rendition>
        <rendition xml:id="xx-large" scheme="css">font-size: xx-large</rendition>
        <rendition xml:id="bold" scheme="css">font-weight: bold</rendition>
        <rendition xml:id="italic" scheme="css">font-style: italic</rendition>
        <rendition xml:id="no_indent" scheme="css">text-indent: none;</rendition>
        <rendition xml:id="indent-1" scheme="css">text-indent: -1em;</rendition>
        <rendition xml:id="indent-2" scheme="css">margin-left: 2em; text-indent: -1em;</rendition>
        <rendition xml:id="right" scheme="css">text-align: right;</rendition>
        <rendition xml:id="left" scheme="css">text-align: left;</rendition>
        <rendition xml:id="l1em" scheme="css">margin-left: 1em;</rendition>
        <rendition xml:id="l2em" scheme="css">margin-left: 2em;</rendition>
        <rendition xml:id="l3em" scheme="css">margin-left: 3em;</rendition>
        <rendition xml:id="r1em" scheme="css">margin-right: 1em;</rendition>
        <rendition xml:id="superscript" scheme="css">font-size: .7em; vertical-align: super;</rendition>
        <rendition xml:id="subscript" scheme="css">font-size: .7em; vertical-align: sub;</rendition>
        <rendition xml:id="hidden" scheme="css">display: none;</rendition>
        <rendition xml:id="underline" scheme="css">text-decoration: underline;</rendition>
        <rendition xml:id="double-underline" scheme="css">border-bottom: 3px double;</rendition>
        <rendition xml:id="v" scheme="free">Describes vertically orientated texts within tables. The HTML
					transfomation rotates these texts per 360° and calculates the size needed.</rendition>
        <namespace name="http://www.tei-c.org/ns/1.0">
          <tagUsage gi="div">Only unnumbered divs used</tagUsage>
        </namespace>
      </tagsDecl>
    </encodingDesc>
    <profileDesc>
      <abstract>
        <p>Historical German text source digitized for the project “Dingler Online – Das digitalisierte Polytechnische Journal”.</p>
      </abstract>
      <langUsage>
        <language ident="de">Neuhochdeutsch</language>
        <language ident="de">German</language>
      </langUsage>
      <textClass>
        <classCode scheme="https://www.deutschestextarchiv.de/doku/klassifikation#dwds">Wissenschaft</classCode>
      </textClass>
    </profileDesc>
  </teiHeader><text type="art_undef" n="5" xml:id="ar339005"><pb n="19" facs="32199916Z/00000043" xml:id="pj339_pb019"/>
            <front>
              <titlePart type="main" rendition="#center">Der Fernsprecher in
								Ueberland-Kraftwerken.</titlePart>
              <titlePart type="sub" rendition="#center">Von <persName role="author" ref="../database/persons/persons.xml#pers">G. <hi rendition="#wide">Quaink</hi></persName>.</titlePart>
              <titlePart type="column">QUAINK, Der Fernsprecher in Ueberland-Kraftwerken.</titlePart>
            </front>
            <body>
              <div type="section">
                <p><cb/>In Ueberlandkraftwerken ist für die wirtschaftliche Betriebsführung; ein
									geregelter Nachrichtendienst unbedingt notwendig. Unterzentralen, das
									Streckenpersonal müssen sich jederzeit von der Betriebsleitung telephonisch
									erreichen lassen, um über Vorkommnisse im Netz Auskunft geben oder Befehle und
									Verhaltungsmaßnahmen entgegennehmen zu können. Dazu die öffentliche Fernsprechanlage
									zu benutzen, hat sich als nicht zweckmäßig erwiesen. Einerseits ist gerade auf dem
									Lande der Fernsprechverkehr sehr eingeschränkt, andererseits sind die jährlich an
									das öffentliche Amt zu zahlenden Gebühren meistens hoher als der Betrag, der zur
									Unterhaltung und Amortisation einer eigenen Fernsprechanlage verbraucht wird. In der
									Regel wird deshalb eine eigene Anlage vorzuziehen sein. Die Leitungen als Kabel in
									die Erde zu betten oder als Freileitungen an besonderen Masten zu führen, erfordert
									recht hohe Anlagekosten. Ein Verfahren, mit Hochfrequenz-Wechselströmen auf den
									Hochspannungsleitungen selbst zu telephonieren, scheint nur für Starkstromanlagen
									mit nicht zu sehr verzweigtem Netz geeignet. Als weitere Möglichkeit bleibt, die
									Fernsprechleitungen an den Hochspannungsmasten zu verlegen, was in der Mehrzahl
									aller Fälle auch geschieht. Solcherart ausgeführte Anlagen haben sich, wenn man
									geeignete Vorrichtungen zum Schutz gegen die Einflüsse des Starkstromes verwendet,
									in der Praxis gut bewährt.</p>
                <p>In der am Hochspannungsgestänge verlegten Fernsprechleitung werden von den
									Kraftleitungen Ströme induziert, die die gleiche Frequenz wie die Starkströme haben.
									Sie erzeugen im Hörer ein andauerndes, lautes Brummen und schließen damit jegliche
									Verständigung aus. Dieser Uebelstand wird vermieden, wenn man für die
									Fernsprechanlage Doppelleitungen verwendet und diese verdrillt, d.h. in bestimmten
									Abständen ihre Lage gegenüber den Kraftleitungen wechseln läßt. Dadurch heben sich
									die induzierten Strome gegenseitig teilweise auf und sind ohne Wirkung auf den
									Fernsprecher. Außer diesen elektromagnetischen Einflüssen treten noch
									elektrostatische auf. Denn das elektrische Feld der Hochspannungen influenziert in
									den Telephonleitungen Spannungen, die an sich bei Gesprächen nicht stören. Tritt
									aber irgendwo ein Fehler in der Isolation der Fernsprechleitungen auf, dann wirkt
									der entstehende Ausgleichstrom störend auf die Verständigung. Deshalb werden nach
									dem Verfahren der Siemens &amp; Halske A.-G. in bestimmten Abständen zwischen die
									Leitungen Drosselspulen <cb/>geschaltet, die in der Mitte ihrer Wickelung geerdet
									sind. Die infolge der gleichgerichteten Ladespannungen von beiden Enden her in die
									Spulen eintretenden Ströme heben wegen ihrer entgegengesetzten Richtung die
									elektromagnetische und damit drosselnde Wirkung der Spulen auf. Diese bilden also
									nur einen einfachen Ohm'schen Widerstand von geringem Betrag, über den die
									Ausgleichströme zur Erde abfließen. Dadurch werden die Ladespannungen nahezu restlos
									aus den Telephonleitungen entfernt. Den Ruf- und Sprechströmen dagegen, die nur in
									einer Richtung durch die Spulen fließen, ist infolge der hohen Selbstinduktion der
									Weg zur Erde versperrt.</p>
                <figure rend="text" xml:id="tx339043a">
                  <graphic url="32199916Z/tx339043a"/>
                  <figDesc>Textabbildung Bd. 339, S. 19</figDesc>
                  <head>Abb. 1.<lb/>Schema eines Hochspannungsschutzes.</head>
                </figure>
                <p>Außerdem besteht noch die Gefahr, daß z.B. bei Drahtbruch einer Hochspannungsleitung
									Starkstrom in die Fernsprechleitungen übertreten kann, was Zerstörungen der
									angeschlossenen Apparate sowie gesundheitsschädliche Wirkungen auf die sie
									bedienenden Personen zur Folge hätte. Daher baut die Siemens &amp; Halske A.-G. vor
									jeden Fernsprechapparat einen Hochspannungsschutz in die Leitung ein. Dieser
									besteht, wie <ref target="#tx339043a">Abb. 1</ref> im Schema zeigt, aus einer
									Grobspannungssicherung in Gestalt einer kräftigen Funkenstrecke,
									Feinspannungssicherungen, Luftleerspannungsableitern und vor allem aus einem
									Fernsprechtransformator, der die unmittelbar leitende Verbindung zwischen
									Fernsprechapparaten und den Leitungen aufhebt und durch eine induktive Koppelung <pb n="20" facs="32199916Z/00000044" xml:id="pj339_pb020"/><cb/>ersetzt. Diese
									Schutzsysteme besitzen einen so hohen Grad von Sicherheit, daß sich dahinter
									Fernsprechstationen üblicher Bauart verwenden lassen. Doch müssen zum Zweck einer
									guten Ruf- und Sprachübertragung die Wickelungen von Fernhörer, Induktor und
									Anrufeinrichtung zum Transformator genau abgestimmt sein. Eine Sonderkonstruktion
									hierfür, und zwar eine Fernsprechzwischenstelle für eine Gesellschaftsleitung, ist
									in <ref target="#tx339044a">Abb. 2</ref> dargestellt. In Vermittelungsstellen, also
									Anlagen mit Strahlenleitungen, muß jeder abgehenden Leitung ein vollständiger
									Hochspannungsschutz vorgeschaltet werden (<ref target="#tx339044b">Abb. 3</ref>).
									Verwendet man Zentralumschalter od. Klappenschränke, so würden bei Verbindung zweier
									Leitungen, die zum Hoch Spannungsgestänge führen, die zugehörigen Transformatoren in
									Reihe geschaltet werden. Um dies zu vermeiden, werden durch einen vor dem
									Klappenschrank liegenden Stöpselumschalter die Leitungen unmittelbar miteinander
									verbunden und dadurch die Transformatoren umgangen. Ein Schlußzeichen erscheint
									trotzdem am Klappenschrank. Hier lassen sich auch Apparate einer
									Haus-Fernsprechanlage anschließen.</p>
                <figure rend="text" xml:id="tx339044a">
                  <graphic url="32199916Z/tx339044a"/>
                  <figDesc>Textabbildung Bd. 339, S. 20</figDesc>
                  <head>Abb. 2.<lb/>Fernsprechzwischenstelle.</head>
                </figure>
                <figure rend="text" xml:id="tx339044b">
                  <graphic url="32199916Z/tx339044b"/>
                  <figDesc>Textabbildung Bd. 339, S. 20</figDesc>
                  <head>Abb. 3.<lb/>Sprech- und Vermittlungsstelle mit Hochspannungsschutz in einem
										Kraftwerk.</head>
                </figure>
                <p><cb/>Zweigt man von der Fernsprechlinie ab, so wird oben am betreffenden Mast ein
										<q>„Abzweigkasten“</q> befestigt, der eine Grobschutzfunkenstrecke enthält. Bei
									Anschlußstellen für tragbare Fernsprecher, wie sie zur Streckenkontrolle auf dem
									ganzen Leitungsweg in gewissen Abständen eingerichtet werden, wird außerdem noch der
									Transformator mit in die Anschlußstelle eingebaut, da sonst der tragbare
									Fernsprecher zu schwer ausfallen würde. Mit Vorliebe ordnet man bei
									Bahnüberführungen am Kreuzungsmast eine vollständige Sprechstelle, einen sogen.
									Mastfernsprecher (<ref target="#tx339044c">Abb. 4</ref>), an, bei dem in einem
									eisernen Gehäuse eine wasserdichte Station zusammen mit dem Hochspannungsschutz
									untergebracht ist. Ist eine Sprechstelle in einer abseits liegenden Monteurwohnung
									oder dergl. zu errichten, so läßt man die Leitungen von einer Ueberführungsstelle,
									in die das gesamte Schutzsystem eingebaut ist (<ref target="#tx339044d">Abb.
									5</ref>), am Mast abzweigen. Dadurch ist der Vorteil erzielt, daß man die abgehende
									Leitung als Niederspannungs-Starkstromleitung, also mit geringeren Kosten, verlegen
									kann.</p>
                <figure rend="text" xml:id="tx339044c">
                  <graphic url="32199916Z/tx339044c"/>
                  <figDesc>Textabbildung Bd. 339, S. 20</figDesc>
                  <head>Abb. 4.<lb/>Mastfernsprecher.</head>
                </figure>
                <figure rend="text" xml:id="tx339044d">
                  <graphic url="32199916Z/tx339044d"/>
                  <figDesc>Textabbildung Bd. 339, S. 20</figDesc>
                  <head>Abb. 5.<lb/>Ueberführungsstelle.</head>
                </figure>
              </div>
            </body>
          </text></TEI>