<?xml version="1.0" encoding="UTF-8"?><?xml-model href="http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng" schematypens="http://relaxng.org/ns/structure/1.0"?><TEI xmlns="http://www.tei-c.org/ns/1.0"><teiHeader>
    <fileDesc>
      <titleStmt><title type="main">Selbsttätige Feuermelder.</title>
        
        
        <editor>
          <orgName>Dingler Online – Das digitalisierte Polytechnische Journal</orgName>
        </editor>
        <respStmt>
          <orgName ref="https://d-nb.info/gnd/1220138-8">Humboldt-Universität zu Berlin</orgName>
          <resp>
            <note type="remarkResponsibility">Projektträger</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName ref="https://d-nb.info/gnd/141535091">
            <surname>Kassung</surname>
            <forename>Christian</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Projektleitung Humboldt-Universität</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName ref="https://d-nb.info/gnd/1204665788">
            <surname>Hug</surname>
            <forename>Marius</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Wissenschaftlicher Mitarbeiter Humboldt-Universität</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName>
            <surname>Zehnder</surname>
            <forename>Deborah</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Projektkoordination</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName>
            <surname>Luzardo</surname>
            <forename>Laura</forename>
          </persName>
          <persName>
            <surname>Schäfer</surname>
            <forename>Una</forename>
          </persName>
          <persName>
            <surname>Bechmann</surname>
            <forename>Antonia</forename>
          </persName>
          <persName>
            <surname>Daniel</surname>
            <forename>Diana</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Studentische Hilfskräfte</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName>
            <surname>Wiegand</surname>
            <forename>Frank</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Programmierung</note>
          </resp>
        </respStmt>
        <respStmt>
          <orgName ref="https://d-nb.info/gnd/5165770-3">Sächsische Landesbibliothek – Staats- und Universitätsbibliothek Dresden</orgName>
          <resp>
            <note type="remarkResponsibility">Kooperationspartner Bibliothek</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName ref="https://d-nb.info/gnd/114684476X">
            <surname>Rohrmüller</surname>
            <forename>Marc</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Projektkoordination Bibliothek</note>
          </resp>
        </respStmt>
        <respStmt>
          <orgName ref="https://d-nb.info/gnd/2007744-0">Deutsche Forschungsgemeinschaft</orgName>
          <resp>
            <note type="remarkResponsibility">Projektförderung</note>
          </resp>
        </respStmt>
        <respStmt>
          <orgName ref="https://d-nb.info/gnd/1064129226">Editura GmbH &amp; Co. KG, Berlin</orgName>
          <resp>
            <note type="remarkResponsibility">Volltextdigitalisierung</note>
          </resp>
        </respStmt>
        <respStmt>
          <persName>
            <surname>Gödel</surname>
            <forename>Martina</forename>
          </persName>
          <resp>
            <note type="remarkResponsibility">Projektkoordination und Basic Encoding nach den Richtlinien der TEI für die Editura GmbH &amp; Co. KG</note>
          </resp>
        </respStmt>
        <respStmt>
          <orgName ref="https://www.clarin-d.de/">CLARIN-D</orgName>
          <resp>
            <note type="remarkResponsibility">Langfristige Bereitstellung</note>
          </resp>
        </respStmt>
      </titleStmt>
      <editionStmt>
        <edition n="1"/>
      </editionStmt>
      <publicationStmt>
        <publisher>
          <email>wiegand@bbaw.de</email>
          <orgName role="project">Deutsches Textarchiv (Dingler)</orgName>
          <orgName role="hostingInstitution" xml:lang="en" ref="https://d-nb.info/gnd/2131094-4">Berlin-Brandenburg Academy of Sciences and Humanities</orgName>
          <orgName role="hostingInstitution" xml:lang="de" ref="https://d-nb.info/gnd/2131094-4">Berlin-Brandenburgische Akademie der Wissenschaften (BBAW)</orgName>
          <address>
            <addrLine>Jägerstr. 22/23, 10117 Berlin</addrLine>
            <country>Germany</country>
          </address>
        </publisher>
        <pubPlace>Berlin</pubPlace>
        <date type="publication">2022-09-26</date>
        <availability>
          <licence target="https://creativecommons.org/licenses/by-sa/4.0/deed.de">
            <p>Die Textdigitalisate des Polytechnischen Journals stehen unter der Creative-Commons-Lizenz CC BY-SA 4.0.</p>
          </licence>
        </availability>
        <idno>
          <idno type="URLWeb">http://digital.slub-dresden.de/id32199916Z</idno>
          <idno type="URLXML">https://dingler.bbaw.de/xml/articles/ar339059.xml</idno>
        </idno>
      </publicationStmt>
      <sourceDesc><bibl type="JA">Selbsttätige Feuermelder. In: Dinglers polytechnisches Journal. Bd. 339. Berlin, 1924. S. 234.</bibl>
        
        <biblFull>
          <titleStmt><title type="main">Selbsttätige Feuermelder.</title>
            
            
          </titleStmt>
          <editionStmt>
            <edition n="1"/>
          </editionStmt>
          <publicationStmt>
            <publisher>Richard Dietze, Verlagsbuchhandlung</publisher>
            <pubPlace>Berlin</pubPlace>
            <date type="publication">1924</date>
          </publicationStmt>
        <seriesStmt><title level="j" type="main" xml:id="pj339">Dinglers polytechnisches Journal. Bd. 339. Berlin, 1924.</title><biblScope unit="volume">1924</biblScope><biblScope unit="issue">339</biblScope><biblScope unit="pages">S. 234</biblScope></seriesStmt></biblFull>
        <msDesc>
          <msIdentifier>
            <repository>SLUB Dresden</repository>
            <idno>
              <idno type="URLWeb">http://digital.slub-dresden.de/id32199916Z</idno>
            </idno>
          </msIdentifier>
        </msDesc>
      </sourceDesc>
    </fileDesc>
    <encodingDesc>
      <projectDesc>
        <p>Optical character recognition and basic TEI encoding by Editura Gesellschaft für
					Verlagsdienstleistungen, Berlin 2012.</p>
      </projectDesc>
      <editorialDecl>
        <hyphenation eol="hard">
          <p>All soft end-of-line hyphenation has been removed. All hard hyphenation coded as U+2010.</p>
        </hyphenation>
        <normalization method="silent">
          <p>No text-decoration elements were captured, such as decorated capital letters at the beginning of
						chapters or text-separators.</p>
          <p>All references to printed sheets were captured.</p>
        </normalization>
        <correction method="markup">
          <p>As far as possible all errata-lists printed in the journal have been realised, using the element
							<gi scheme="TEI">orig</gi> to mark the original text and <gi scheme="TEI">corr</gi> to mark
						the correction given in the errata-list.</p>
        </correction>
        <quotation marks="all">
          <p>All passages set off by quotation marks were marked by the element <gi scheme="TEI">q</gi>
						including the quotation mark inside the tag. In case of repeating quotation marks in front of
						each line, only the first and the last quotation mark was obtained. And the element <gi scheme="TEI">q</gi>'s @type-attribute was set to the value „preline”.</p>
        </quotation>
      </editorialDecl>
      <tagsDecl>
        <rendition xml:id="roman" scheme="css">font-family: "times new roman", times, serif;</rendition>
        <rendition xml:id="wide" scheme="css">letter-spacing: 2pt;</rendition>
        <rendition xml:id="center" scheme="css">text-align: center;</rendition>
        <rendition xml:id="small" scheme="css">font-size: .8em;</rendition>
        <rendition xml:id="x-small" scheme="css">font-size: x-small;</rendition>
        <rendition xml:id="xx-small" scheme="css">font-size: xx-small;</rendition>
        <rendition xml:id="large" scheme="css">font-size: large;</rendition>
        <rendition xml:id="x-large" scheme="css">font-size: x-large;</rendition>
        <rendition xml:id="xx-large" scheme="css">font-size: xx-large</rendition>
        <rendition xml:id="bold" scheme="css">font-weight: bold</rendition>
        <rendition xml:id="italic" scheme="css">font-style: italic</rendition>
        <rendition xml:id="no_indent" scheme="css">text-indent: none;</rendition>
        <rendition xml:id="indent-1" scheme="css">text-indent: -1em;</rendition>
        <rendition xml:id="indent-2" scheme="css">margin-left: 2em; text-indent: -1em;</rendition>
        <rendition xml:id="right" scheme="css">text-align: right;</rendition>
        <rendition xml:id="left" scheme="css">text-align: left;</rendition>
        <rendition xml:id="l1em" scheme="css">margin-left: 1em;</rendition>
        <rendition xml:id="l2em" scheme="css">margin-left: 2em;</rendition>
        <rendition xml:id="l3em" scheme="css">margin-left: 3em;</rendition>
        <rendition xml:id="r1em" scheme="css">margin-right: 1em;</rendition>
        <rendition xml:id="superscript" scheme="css">font-size: .7em; vertical-align: super;</rendition>
        <rendition xml:id="subscript" scheme="css">font-size: .7em; vertical-align: sub;</rendition>
        <rendition xml:id="hidden" scheme="css">display: none;</rendition>
        <rendition xml:id="underline" scheme="css">text-decoration: underline;</rendition>
        <rendition xml:id="double-underline" scheme="css">border-bottom: 3px double;</rendition>
        <rendition xml:id="v" scheme="free">Describes vertically orientated texts within tables. The HTML
					transfomation rotates these texts per 360° and calculates the size needed.</rendition>
        <namespace name="http://www.tei-c.org/ns/1.0">
          <tagUsage gi="div">Only unnumbered divs used</tagUsage>
        </namespace>
      </tagsDecl>
    </encodingDesc>
    <profileDesc>
      <abstract>
        <p>Historical German text source digitized for the project “Dingler Online – Das digitalisierte Polytechnische Journal”.</p>
      </abstract>
      <langUsage>
        <language ident="de">Neuhochdeutsch</language>
        <language ident="de">German</language>
      </langUsage>
      <textClass>
        <classCode scheme="https://www.deutschestextarchiv.de/doku/klassifikation#dwds">Wissenschaft</classCode>
      </textClass>
    </profileDesc>
  </teiHeader><text type="art_undef" n="59" xml:id="ar339059">
            <front>
              <titlePart type="main" rendition="#center">Selbsttätige Feuermelder.</titlePart>
              <titlePart type="column">[Selbsttätige Feuermelder.]</titlePart>
            </front>
            <body>
              <div type="section">
                <p><cb/>Um Gebäude vor Feuersgefahr nach Möglichkeit zu schützen, sind schon viele
									Vorsichtsmaßregeln getroffen und Meldeapparate gebaut worden. Feuermeldeanlagen sind
									um so höher zu bewerten, je sicherer und schneller sie ein Feuer anzuzeigen
									vermögen. Gerade in Räumen, in denen z.B. Waren von hohem Wert oder feuergefährliche
									Stoffe lagern, und in denen sich nicht ständig Personen aufhalten, ist ein guter und
									sicher arbeitender Feuerschutz besonders wichtig, ebenso in Theatern oder auf
									Schiffen, wo ein Feuer, wenn es einmal entstanden ist, sich schnell auszubreiten
									vermag.</p>
                <p>Auch ein gutes und zuverlässiges Wachpersonal vermag eine entstehende Feuersgefahr
									nicht immer so frühzeitig zu melden, wie die selbsttätigen Feuermelder. Diese
									zeichnen sich dadurch aus, daß sie jedes Feuer ohne Mitwirkung eines Menschen schon
									im Entstehen einer Alarmstelle melden und so ermöglichen, daß die Gefahr rechtzeitig
									bekämpft werden kann.</p>
                <p>Der einfachste der von der Siemens &amp; Halske A.-G. gebauten selbsttätigen
									Feuermelder ist der sogen. Schmelzlotmelder (Bild 1), der nach den Angaben des
									Branddirektors Gordyn (Amsterdam) hergestellt wird. Zwei federnde Blechstreifen
									werden durch eine Legierung, die schon bei 75° C schmilzt, zusammengelötet. Bei
									Entstehen eines Feuers genügt schon eine kleine Hitzewelle, die Verbindung zu lösen
									und damit die Kontaktstelle zu öffnen. Die Anlage arbeitet mit Ruhestrom. Sowie
									durch das Oeffnen der Lötstelle der Melder in Tätigkeit tritt, wird in der Zentrale
									(Portier, Wache oder andere Zentrale) am Empfangsapparat das Feuersignal
									abgegeben.</p>
                <figure rend="text" xml:id="tx339359a">
                  <graphic url="32199916Z/tx339359a"/>
                  <figDesc>Textabbildung Bd. 339, S. 233</figDesc>
                  <head>Abb. 1.<lb/>Schmelzlotmelder. </head>
                </figure>
                <figure rend="text" xml:id="tx339359b">
                  <graphic url="32199916Z/tx339359b"/>
                  <figDesc>Textabbildung Bd. 339, S. 233</figDesc>
                  <head>Abb. 2.<lb/>Maximalmelder.</head>
                </figure>
                <p>Eine andere Art der selbsttätigen Feuermelder ist der Maximalmelder. Er hat vor allem
									den großen Vorzug, daß er auf jede beliebige Temperatur einstellbar ist, auf die er
									ansprechen soll, und zwar bei der normalen Ausführung in einem Bereich von 40 bis
									90° Celsius in Stufen von 5°. Eine U-förmig gebogene Arbeitsfeder befindet sich
									einer zweiten Feder, der Kontaktfeder, gegenüber. (Bild 2.) Die Arbeitsfeder ist aus
									zwei verschiedenen Metallen mit weit auseinanderliegenden Ausdehnungskoeffizienten
									zusammengeschweißt, sie biegt sich also bei Erwärmung infolge der ungleichen
									Ausdehnung der beiden Metalle. Je <cb/>nachdem, ob Kontaktöffnung (für
									Ruhestromschaltung) oder Kontaktschluß (für Arbeitsstromschaltung) in Betracht
									kommt, liegt das Material mit dem höheren Ausdehnungskoeffizienten auf der Innen-
									oder Außenseite des gebogenen Streifens. Durch Drehen einer Exzenterscheibe läßt
									sich die Kontaktfeder verstellen. Hierdurch wird die Meldung früher oder später,
									d.h. bei niedrigerer oder höherer Temperatur erfolgen.</p>
                <p>Die Apparate können auch mit zwei Arbeitsfedern ausgerüstet werden, so daß bei diesen
									sogen. Doppelmeldern jede der beiden Federn auf eine andere Meldetemperatur
									eingestellt werden kann.</p>
                <figure rend="text" xml:id="tx339359c">
                  <graphic url="32199916Z/tx339359c"/>
                  <figDesc>Textabbildung Bd. 339, S. 233</figDesc>
                  <head>Abb. 3. Schutzgehäuse f. Max malmelder m. federnder Aufhängung.</head>
                </figure>
                <p>Zum Aufhängen des in ein korbartiges Schutzgehäuse eingebauten Melders an der Decke
									oder der Wand dient ein federndes Zwischenstück, das den Melder gegen
									Erschütterungen schützt (Bild 3). In Räumen, wo besonders starke Erschütterungen zu
									befürchten sind (Schiffen), die unter Umständen eine momentane Trennung der Kontakte
									und somit eine Meldung hervorrufen könnten, wird der Melder vorteilhaft in einer
									Pendeldose aufgehängt, in der er durch eine federnde Spirale gehalten wird.
									Nötigenfalls erhalten die Melder auch ein wasser- und gasdichtes Schutzgehäuse.</p>
                <p>Eine dritte Art der selbsttätigen Feuermelder ist der sogen.
										<q>„Differentialmelder“</q>. Ein U-förmig gebogenes, vollständig geschlossenes
									Glasrohr ist in beiden Schenkeln bis über die Hälfte mit Quecksilber gefüllt. Ueber
									dem Quecksilber befindet sich eine geringe Menge einer leicht verdampfenden
									Flüssigkeit. In die unteren Hälften der Schenkel sind in das Glasrohr Platindrähte
									eingeschmolzen, die als Zuleitungen für den Ruhestrom dienen.</p>
                <figure rend="text" xml:id="tx339359d">
                  <graphic url="32199916Z/tx339359d"/>
                  <figDesc>Textabbildung Bd. 339, S. 233</figDesc>
                  <head>Abb. 4.<lb/>Empfangseinrichtung einer selbsttätigen Feuermeldeanlage.</head>
                </figure>
                <p>Der eine Schenkel des Melders besteht aus bedeutend dickerem Glase als der zweite, er
									wird also die Wärme weniger schnell durch sich hindurchgehen lassen. <pb n="234" facs="32199916Z/00000360" xml:id="pj339_pb234"/><cb/>Jeder Temperatur entspricht
									bekanntlich ein gewisser Dampfdruck; es wird also in dem Schenkel mit dem dünneren
									Rohre bei steigender Temperatur ein Ueberdruck entstehen und das Quecksilber daher
									in diesen Schenkel fallen. Sinkt es hierbei bis unter den stromzuführenden Kontakt,
									so wird der Ruhestromkreis unterbrochen und damit das Feuersignal abgegeben.</p>
                <p>Die Differentialmelder sind unabhängig von der Anfangstemperatur, sie sprechen ledig
									ich auf schnelle Temperaturänderungen an und finden daher besonders vorteilhaft in
									Räumen mit schwankenden Temperaturen Verwendung. Auf Dachböden z.B. müßten
									Maximalmelder im Sommer auf eine höhere Temperatur eingestellt werden als im Winter,
									damit nicht die Sonnenstrahlen bereits eine Feuermeldung hervorrufen. Diese
									Aenderungen der Einstellung sind beim Differentialmelder überflüssig.</p>
                <p>Differentialmelder verwendt man nur gemeinsam mit Maximalmeldern. Bei jenen ist es
									nämlich möglich, <cb/>daß durch ein sich nur langsam entwickelndes Feuer (z.B.
									Schwelfeuer) im Differentialmelder das Quecksilber nicht weit genug in dem dünneren
									Schenkel sinkt, da dann die Wärme Zeit genug hat, in beiden Schenkeln gleichmäßig
									bis in das Innere vorzudringen. Die Alarmmeldung bleibt also aus. In diesem Falle
									übernimmmt der Maximalmelder die Feueranzeige.</p>
                <p>Auf der Zentrale kommt die Feuermeldung am Empfangsapparat (Bild 4) an, wo durch das
									Abfallen von Fallklappen oder durch das Aufleuchten von Glühlampen die Gefahr
									angezeigt wird.</p>
                <p>Tritt in der Anlage ein Drahtbruch auf, so wird durch besondere Schaltung erreicht,
									daß dieser unterschiedlich von Feuermeldungen angezeigt wird. Dadurch ist eine
									Kontrolle der Anlage auf Leitungsstörungen gegeben und wird außerdem vermieden, daß
									in einem solchen Falle der Feuerwehr ein falscher Alarm gemeldet wird.</p>
                <p rendition="#right"><hi rendition="#wide"><persName role="author" ref="../database/persons/persons.xml#pers">Buchholtz</persName></hi>.</p>
              </div>
            </body>